Wednesday, February 25, 2009

Setting for VRU


Below are some setting I used at one of the Vapor recovery site. It's Runs smoothly using this set up figure. You can try it if you want. 

BED


Set Point
895 Sec

Adsorption
1790 Sec

Cycle time
5 Sec

Valve Shift A1/B1
5 Sec

Valve Shift A2/B2
830 Sec

Total Desorption
240 Sec

Equalisation 1
40 Sec

Equalisation 2
15 Sec

Max time between regeneration
240 Sec

Min time between regeneration
30 Sec

No of regeneration before economy
3 Sec




TIMER


T1 DISP
15

T2 DISP
15

T3 Restart delay vacuum pump
30

T4 Start between vacuum and Glycol pump
30

T5 Start between LV315 -> P301
9

T7 Start Between AV321-> P321
5

T10 FA-305, Low Flow Alarm, Absorbent inlet
75

T11 DISP
0

T12 FA-461 Low Flow Alarm, Glycol Circ P261
15

T13 DISP
0

T14 AV462 Glycol drain valve, Fmty Opening Time
0

T15 DISP
0

T18 DISP
0

T20 LS+107 High Level drip-tee
3

T22 DISP
5

T25 LA+314 High Level absorher-restart
90

T26 LA-314 Low Level absorher-restart
90

T31 PA+101 High Pressure, Vapour inlet line
10

T32 PA-101 Low Pressure, Vapour inlet line
10

T34 Equalize 1, Hold register, before alarm
30

T35 PA+221 High Pressure, Vacuum not obtain
30

T36 PA-221 Low Pressure, Cavitations
12

T37 Release Shift to Restoration 2
75

T38 PA-AV 262, By Pass-Valve Open Too Long
60

T41 PA-901, Low Pressure, Instrument air
12

T43 QA+155 High Co Cone Outlet Hed's
600

T44 QA+155 High Co Cone Outlet Hed's
120

T46 TA+265, High Temp, Vac Pump P261, Restart
10

T48 DISP
10

T50 Communication Fail
15




EMMISION


Q1 155
High Limit QS+155

Co analyser outlet bed's
900PPM Co




Q1 156
High Limit QS+156

Hc analyser outlet bed's
42g.Hc/NM³




FLOW



Limit     FS+101

F1 101
High Loading Signal

Flow Vapour inlet to bed's
4,900m³/h




FQ1 101
FQS+101


Regeneration

Flow Amount Vapour inlet
50m³




LEVEL






HIGH LIMIT
LOW LIMIT
LIMIT
LIMIT

L1 314
 LS+314
 LS-314
V310
MW1

Level Absorher, Vessel, adsorbent
HIGH
LOW
HEIGHT
MASSWEIGHT


65%
5%
1,000mm
750kg/m³








HIGH LIMIT
LOW LIMIT
LIMIT
LIMIT

L1 414
LS+414
LS-414

MW2

Level Absoher, Vessel, Glycol
HIGH
LOW

MASSWEIGHT


80%
5%

1,070kg/m³

PRESSURE









DESCRIPTION
HIGH LIMIT
LOW LIMIT
LIMIT
LIMIT
P 101                 Pressure Vapour    inlet to VRU
PS+101                      HIGH                     40mbar
PS-101                                         LOW                                   -30mbar


Bed Pressure              p1 211-V110-               P1 231-V130-
PS+-Bed                       HIGH                       1300mbar
PS-Bed                         Equalize 2                950mbar
PS-Bed                     Equalize 1                 850mbar
PS---Bed                   Shift to Desorption 2 130mbar
P 221                 Pressure inlet Vacuum Pumps
PS+221                         HIGH                        500mbar
PS-221                    Cavitations                50mbar
PS+_AV_ByPass        Close AV_262        60mbar
PS-_AV_ByPass         Open AV-262            40mbar
P1 312               Pressure Absorher Vessel V310
PS+312                            HIGH                         400mbar



TEMPERATURE



HIGH LIMIT

T1 111
TS+111

Temperature
HIGH

Bed V11o Bottom
100°c




T1 112
TS+112

Temperature
HIGH

Bed V110 Top
100°c




T1 131
TS+131

Temperature
HIGH

Bed V130 Bottom
100°c




T1 132
TS+132

Temperature
HIGH

Bed V130 Top
100°c




T1 265
TS+265

Temperature in
HIGH

Vacuum Pump P261
65°c















VOC



Q1 101
Factor
Vapour analyzer
macicolor weight
Flow vapour inlet
58g/mol


VOC_Volume
Density recovered product
Accumulated
680kg/m³
recover VOC


PID PARAMETER

PCV OR PCV312



Process Value

Set point value
150mbar
Output value

Output hand
-0.0


GAIN R:-
-0.500
I-Parameter
3.0
D-Parameter
-0.0


PID PARAMETER

LIC314 OR LCV 314



Set pointy value
27.0%
output hand
-0.0%


GAIN R:-
-0.130
I-Parameter
12.0
D-Parameter
1.0


PID PARAMETER

PIC221



Set pointy value
315mbar
output hand
-0.0%


GAIN R:-
0.015
I-Parameter
2.5
D-Parameter
0.0


PID PARAMETER

PIC101 OR PT101



Set pointy value
2mbar
output hand
20.0%


GAIN R:-
-0.200
I-Parameter
8.0
D-Parameter
-0.0

I did some adjustment on the Timer due to some problem and frequently shut down.
TIMER


DEVICE
FROM
TO
T3
30
12
T4
30
11
T14
0
6
T37
75
6

I did some adjustment on the Timer due to some problem and frequently shut down.
PID PARAMETER

PIC221



Set pointy value
250mbar
output hand
14


GAIN R:-
0.090
I-Parameter
1.0
D-Parameter
0.0

GAU_151 Exhaust fan Freq.con.not ready/fail.