Below are some FUSION setting to start with.
Fusion = FCL (Forcord Controller System)
Recommended for Fusion console PC is a P4 and runs on XP. You can use a P3 PC but it will surely runs slow. Also you will need MS OFFICE.
Recomended distence between a power cable and communication cable is at least 20cm with dedicated conduit. There is no join allow between cables. Only 1 joint from Fusion to Dispenser. For current loop communication cable must use (0.5mm twisted and shielded cable)
For a motorcycle dispenser you will need two different cable to connect to 2 different CPU boar in the dispenser. another reason is Fusion will not communicate to 2 CPU using 1 Cable even though its run on current loop.
Jumper on LOOP board
Wayne = OFF
Gilbarco = ON
IP for Fusion is 192.168.1.20.
Login: ADMIN
Password: (enter)
Configuration.
-> Generic.
MODUEL = FORCORT MANAGER DESCRIPTION
-> DEVICES -> OTHERS (SERCH) -> WIZARD
-> Configuration -> maintanance -> apply configuration.
Port name:- dev/ttyUSB0
/dev/gribport1
Operation -> Forcort -> Forcourt Status (Current Status)
Change Price
Configuration -> Price -> Price Change
Submit
Price Change Update.
Saturday, July 19, 2008
Friday, July 18, 2008
FUSION
FUSION or its original name last time was TEQUILA is a for-cord control system by Dresser Wayne. Install some in Malaysia and thru my observation it is a very good controller and most important Robust. Below brousher will explain more detail of its capability.
Saturday, March 15, 2008
How to clear S01 to S06 statistic on Wayne 3V's & 4V's
- Select the statistic number and press "enter" key
- Press "#" key and you will see at the sales amount showing "clear totals"
- Press the "enter" key and the sales amount will show "PASS"
- Type the password "142"
- Press "enter" key to erase the data
There you go now you have it all clear.
- Press "#" key and you will see at the sales amount showing "clear totals"
- Press the "enter" key and the sales amount will show "PASS"
- Type the password "142"
- Press "enter" key to erase the data
There you go now you have it all clear.
Tuesday, February 26, 2008
Oil Co's Safety Terms.
I would like to share some of the safety terms that usualy used by the Oil Companys Especially Exxon.
WCS = Work Control System. safety
WCP = Work Control Procedure
SWP = Safe Work Procedure
PTW = Permit To Work
JSA = Job Safety Analysis
SPSA = Safe Performance Self Assesment
LPO = Lost Prevention Observation
RA = Risk Assessment
HI/PI = Hazard Identification / Potential Incident
NM = Near Miss
JCF = Job Clearance Form
CSD = Critical Safety Device
MSDS = Material Safety Data Sheet
USV = Unanounce Site Visit
LOTOTO = Log Out Tag Out Test Out
Psssss date posted is as per my diary
WCS = Work Control System. safety
WCP = Work Control Procedure
SWP = Safe Work Procedure
PTW = Permit To Work
JSA = Job Safety Analysis
SPSA = Safe Performance Self Assesment
LPO = Lost Prevention Observation
RA = Risk Assessment
HI/PI = Hazard Identification / Potential Incident
NM = Near Miss
JCF = Job Clearance Form
CSD = Critical Safety Device
MSDS = Material Safety Data Sheet
USV = Unanounce Site Visit
LOTOTO = Log Out Tag Out Test Out
Psssss date posted is as per my diary